Digital Solutions
SQ Guide System
SQ Guide System
SQ GUIDE is a Digital Implant Guide System optimized for SQ Implant Fixture
Full Solution Guide System
- Place the implant in the correct position by virtually doing the implant placement through the software
- Insert the implant in where you make a plan and have one-day prosthetic setting
Exclusive Guide System for SQ Implant
- Computer guided implant placement for SQ Implant that has the advanced SLA surface
- SQ Implant Fixture Size
- Diameter: Ø3.5, Ø4.0, Ø4.5, Ø5.0
- Length: 7.0mm, 8.0mm, 10.0mm, 12.0mm, 14.0mm
SQ GUIDE Sleeve
- Titanium metal sleeve is used
- SQ GUIDE Sleeve information
- Base Offset: 9.0mm
- Inner Diameter: Ø5.35
- Length: 3.5mm, 4.5mm
SQ GUIDE Software
- SQ GUIDE is available with Dentiq Guide S/W or Implant Studio S/W.
- Chair-side production is possible with DENTIS Implant and sleeve library
SQ Surgical Kit
Why SQ Guide Is Special?
Safety
- Add irrigation function to prevent bone loss and Bone Heating
- Available exclusively for Dentis SQ Implant.
- Using a metal sleeve, prevents contamination of the surgical site by guide resin, which can be made during drilling
Accuracy
- With the initial drill (F Ø3.5 STEP Drill), you can drill without slipping because of Side Cutting function
- Drilling can be done precisely because the lower end of the trailing drill is fixed to the previously drilled place. And at the upper end or the guide hole, the barrel part of the drill is tightly fixed with the sleeve
- Sleeve Contact
Convenience
- By adopting the multi-stage drill, the number of drills can be minimized and the operation can be performed quickly.
- Added convenience: Tissue Punch, Flattener, Profiler Drill, etc.
SQ GUIDE Kit Drill Specs
Initial Drill
- Used to form holes that ensure precise orientation at the initial stage
- Recommended RPM: 800~1,200
Size | Product Code |
---|---|
Ø2.2 | DSQGID22 |
Ø3.5 | DSQGID35 |
※ Irrigation function of drill part, prevention of bone heating
Initial Drill
- Used to form holes that ensure precise orientation at the initial stage
- Recommended RPM: 800~1,200
Size | Product Code |
---|---|
Ø3.5 | DSQGCS35 |
Ø4.0 | DSQGCS40 |
Ø4.5 | DSQGCS45 |
Ø5.0 | DSQGCS50 |
※ Additional purchase: Ø3.5, Ø4.0, Ø4.5
STEP Drill
- Used to form diameters and lengths for fixture placement, drilled ahead of drilled space
- Design with multi-layer structure
- Recommended RPM: 800~1,200
Length/Size | 2.2 | 3.5 | 4.0 | 4.5 | 5.0 |
---|---|---|---|---|---|
8.0mm | DSQGSTD 2208 | DSQGSTD 3508 | DSQGSTD 4008 | DSQGSTD 4508 | DSQGSTD 5008 |
10.0mm | DSQGSTD 2210 | DSQGSTD 3510 | DSQGSTD 4010 | DSQGSTD 4510 | DSQGSTD 5010 |
12.0mm | DSQGSTD 2212 | DSQGSTD 3512 | DSQGSTD 4012 | DSQGSTD 4512 | DSQGSTD 5012 |
14.0mm | DSQGSTD 2214 | DSQGSTD 3514 | DSQGSTD 4014 | DSQGSTD 4514 | DSQGSTD 5014 |
16.0mm | DSQGSTD 2216 | DSQGSTD 3516 | DSQGSTD 4016 | DSQGSTD 4516 | DSQGSTD 5016 |
※ Irrigation function of drill part, prevention of bone heating
Drilling Protocol for Ø5.0x10.0mm Fixture(Offset 9.0mm)
Drilling Protocol for Ø5.0x10.0mm Fixture(Offset 11.0mm)
Drilling Protocol for Ø5.0x10.0mm Fixture(Offset 13.0mm)
SQ GUIDE System Workflow